StandardComponents
Initsstandardconfiguration,theLightViper1808/0808ismadeupofthefollowingprimarycomponents.
VIM‐1808
TheVIM‐1808containsthesystemclock.Itcanbeplacedateitherend(headortail)ofthesystem.Ifusinganexternalclock
however,theVIM‐1808needstobeconnectedtothisclock.TheVIM‐1808andVIM‐0808areidenticalexceptthattheVIM‐
1808containsthesystemclockandan“external”clockinputconnector.
VIM‐0808
TheVIM‐0808canbeplacedateitherend(headortail)ofthesystem.
FiberCable(TFC‐0000‐04)
Forliveproduction,TFC‐0000‐04tacticalmilitarygradefiberwithTAC‐4ConnectorsisrequiredbetweentheVIM‐1808and
VIM‐0808.NeutrikOpticalCon®tacticalfiber(TFC‐0000‐02‐OC)isalsoavailableforsimilarapplications.Forinstallationswhere
thefiberwillbepulledthroughconduit,eitherVFC‐0000‐D
(PVCfiber)orVFC‐0000‐DP(Plenumratedfiber)withSTconne ctor
terminationsisrecommended.Thereisalsoanoptionfora“PullingEye”whichcanbespecifiedbyaddingan“E”tothepart
numbersabove(VFC‐0000‐DE;VFC‐0000‐DPE).Thisoptionincludesa strainreliefand
pullingeyeononeendofthefiberoptic
cable.
Lightweightmilitary“tacticalgrade”fiber‘cable’(TFC‐0000‐04)carriesthedigitalsignalbetweenLightViperdevices.Neutrik
OpticalCon®tacticalcableisalsoavailable.Forinstallationuse,eitherPVCorPlenumratedfiberisrecommended(VFC‐0000‐
D,VFC‐0000‐DP).
TAC‐4andOpticalCon®Panels
(VPL‐11,VPL‐12&VPL‐13).These1Urackpanelsinclude(1),(2)or(3)TAC‐4connectorsrespectivelyallowingforconnection
betweentheTAC‐4panelmountconnectorandtheSTconnectorsontheVIM‐1808/0808.NeutrikOpticalConpanelmount
connectorscanalsobemountedonthesepanelsratherthanTAC‐4connectors.Specifybyusingthesuffix“OC”(Ex.“VPL‐11‐
OC).TAC‐4andNeutrikOpticalConconnectorscanalsobefitdirectlyonthechassisofthe VIM‐1808/0808system.In
applicationssuchasthese,rackearsandVPLpanelsarenotrequired.AllLightViperunitscomestandardwithSTconnectors
unlessotherwisespecified.
Send/ReturnCables(VCB‐ADXM,VCB‐ADXF)
ThesecablesconnecttheVIM‐1808/0808totheanaloginputs/outputsofyoursystem.Avarietyofcablestoconnecttoother
digitalconsolesanddevicesarealsoavailable.
OptionalComponents
AdditionalcomponentscanbeaddedtotheLightViper1808/0808forincreasedfunctionality.
DMX4LightingControlInterface
MD‐3MultiControlInterface
InapplicationswhereyouwantRS‐422,RS‐232orMidicontrolinaVIM‐1808/0808system,apairofMD‐3deviceswill
translatedthiscontrolprotocolintoTTLdataforinputto/outputofthe“ControlCircuit”connectorontheVIM‐1808/0808.
**Pleaserefertopage13foracompletelistandphotosoffiber‐opticcabletypesaswellascopperinterface